Elan COM2 Manual de usuario

Busca en linea o descarga Manual de usuario para Conmutadores De Vídeo Elan COM2. C2/COM2 and g! - ELAN Home Systems Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 8
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 0
TechNotes
Revision 5/25/2011
ELAN C2/COM2 and S86/M86
Integration with g! System
Overview:
The C2 and COM2 Communication Controllers are designed to integrate a telephone system into
the ELAN g! System HC-Series Controller so they can be used for things such as “Whole House
Paging” and opening doors.
Requirements:
You will need the following:
1. An ELAN g! System HC-Series Controller.
2. An ELAN COM2 or C2 Communication Controller with firmware version 1.6.1.3 or higher.
3. At least one ELAN DSS3, DSF3 or DSC3 Door Stations.
4. An ELAN M86A or S86 System (single or multiple chassis) with firmware version 2.3.1.2
or higher.
5. An amplifier (only if using an S86AVP).
6. A telephone to use as a “house” phone.
7. If possible, a telephone line (or, a line simulator and another telephone).
8. Appropriate Cat5 and speaker cables (as directed by Installation Manuals).
Steps to complete desired action:
1. Referring to the C2/COM2 installation manual, connect the Door Station to the C2/COM2
rear panel.
2. Test the door station by pressing the doorbell button. The front panel of the C2/COM2
indicates that the doorbell was activated.
3. Referring to the C2/COM2 installation manual, connect the telephone and incoming
telephone line/line simulator to the C2/COM2 rear panel.
4. Test the telephone interface with the C2/COM2 by picking up the phone, checking for dial
tone and Off-Hook indication on the C2/COM2 front panel.
5. Referring to the C2 installation manual, connect an ELAN standard Cat5 cable between the
VIANET ports of the C2/COM2 and S86/M86A.
NOTE: The current COM2 manual does NOT yet reference its VIANET capability, which
was added later in COM2 firmware 1.6.1.3.
6. If multiple S86/M86A chassis are being used, connect an ELAN standard Cat5 cable
between the VIANET ports of all chassis.
7. Test VIANET communications by pressing the doorbell button on the door station.
Assuming they have not been configured and programmed otherwise, all S86/M86A
Zones will turn on for the duration of the door bell event (approximately 3 to 5 seconds).
www.elanhomesystems.com/dealer Tech Support: 800-622-3526
Page 1 of 8
Vista de pagina 0
1 2 3 4 5 6 7 8

Indice de contenidos

Pagina 1 - TechNotes

TechNotes Revision 5/25/2011 ELAN C2/COM2 and S86/M86 Integration with g! System Overview: The C2 and COM2 Communication Controllers are designed to

Pagina 2 - Page 2 of 8

Steps to complete desired action (continued): 8. If using an M86, connect it to the HC Controller referring to the ELAN M86 integration note. Veri

Pagina 3

g! System Basic Applications and Configuration: With respect the VIANET-based Doorbell and Whole House Paging, g! System HC-Series Controller operati

Pagina 4 - Page 4 of 8

g! System Advanced Applications and Configuration: There are times when the need arises to have the g! System HC-Series Controller perform certain op

Pagina 5

Programming Jump to Video on Doorbell (With return to Home Page): NOTE: For this exercise, assume that the desired C2/COM2 trigger event is DB (Door

Pagina 6 - Page 6 of 8

7. In the Event Map screen, under Commands select Add. 8. In the Add Command window, under System Family select General System. 9. Under Command G

Pagina 7

Figure 4- Configure Event Map Command for Delay Execution 19. In the Event Map screen, under Commands select Add again. 20. In

Pagina 8 - Page 8 of 8

Figure 5- Configure Event Map Command for Jump to Home Page 24. Add additional commands as needed for the rest of the Touch Screens in the system.

Comentarios a estos manuales

Sin comentarios