4 of 11
OLEXL TS2 UPDATE PROCEDURE
NOTE: Use the following procedure to convert an OleXL for use as a TS2, this update is not required for
TS2 keypads. This procedure requires a PC with a USB port, a USB “A” to USB “Mini-B” cable, the
ELAN Firmware Update utility included with g!Connect Pro, the ELAN Common Resources Library, and
the OleXL.
OleXL-TS2 Firmware update procedure:
1. Verify that you have g!ConnectPro version 5.2 Build 583 or newer
2. Run the Firmware Updater: Click Start/All Programs/ELAN Home Systems/ Tools/Firmware Updater.
3. Using the USB-USB-mini cable connect the TS2 to the PC. Remove all other connections to the
TS2, it will be powered by the USB connection during the update.
Note: if this is the first time an ELAN USB device is connected to your PC you may see a pop-up
message as the USB device driver installation is completed which may require a reboot of your
system.
4. From the Device drop down menu select TS2. The firmware files window will populate with the
available firmware files.
5. Click the Transfer button. The Status window will indicate the progress as the firmware is
downloaded to the device.
6. Wait for the download to complete then click done to close the update utility. Disconnect the TS2
from the PC.
7. Replace the OleXL film with the TS2 film, see the TS2 Installation manuals for detailed instructions.
8. Set the Z-NET/VIA!Net switch on the back of the unit to the VIA!NET position.